Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Animals (Basel) ; 13(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958107

RESUMO

Diploid and triploid Atlantic salmon show distinct physiological differences including heart, brain, and digestive system morphology, propensity for certain deformities, temperature tolerance as eggs and once hatched, and different nutritional requirements. Whilst several studies have looked in detail at the rate of embryogenesis in diploid salmon, no study has compared the rate of embryogenesis between ploidies from fertilisation to hatch. This study based its assessment on a seminal paper by Gorodilov (1996) and used the same techniques to compare the rate at which triploid and diploid embryos developed morphological characteristics. Whilst no significant difference was found, this study provides well-needed justification for the assumption that both ploidies develop at the same rate and gives scientific weight to studies which involve manipulation at these stages of development. Two factors that did differ, however, were the timing of hatch, and mortality. Triploids hatched more quickly than diploids and reached 50% hatch at a significantly earlier point. Triploids also suffered from a significantly higher rate of mortality.

2.
PLoS One ; 18(10): e0292319, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37792726

RESUMO

The current methods used for producing triploid Atlantic salmon are generally reliable but not infallible, and each batch of triploids must be validated to ensure consumer trust and licensing compliance. Microsatellites have recently been shown to offer a cheaper and more convenient alternative to traditional flow cytometry for triploidy validation in a commercial setting. However, incubating eggs to at least the eyed stage for microsatellite validation poses challenges, such as reduced quality and performance of triploids produced from later eggs in the stripping season. To address these issues, we propose another option: extracting DNA from recently fertilised eggs for use in conjunction with microsatellite validation. To achieve this, we have developed an optimized protocol for HotSHOT extraction that can rapidly and cheaply extract DNA from Atlantic salmon eggs, which can then be used for triploidy validation through microsatellites. Our approach offers a simpler and more cost-effective way to validate triploidy, without the need for skilled dissection or expensive kits.


Assuntos
Salmo salar , Triploidia , Animais , Salmo salar/genética , Repetições de Microssatélites/genética , Diploide
3.
Asian Cardiovasc Thorac Ann ; 31(7): 624-632, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37271972

RESUMO

BACKGROUND: Endovascular aortic arch repair (EAR) has emerged as an alternative to open surgical repair. A growing interest in endovascular repair techniques for aortic arch aneurysms and dissection has been met with a focus on the clinical efficacy of EAR devices. We present multicentre comparative data on the clinical outcomes associated with EAR using the double- and triple-branched configurations of the RELAY™ (Terumo Aortic, Scotland, UK) endograft. METHODS: Multicentre data on EAR procedures, carried out from January 2019 to January 2022, using the double- and triple-branched RELAY™ endograft were collected prospectively. Follow-up data were collected at 30 days, 6 months, 12 months, and 24 months postoperative. Retrospective descriptive analysis, logistic regression, and Kaplan-Meier analysis were carried out on procedural and follow-up data. RESULTS: A total of 131 patients were included in the series. In total, 103 and 28 patients were treated with the double-branched and triple-branched RELAY™ endograft, respectively. Over the 24-month follow-up period, zero mortality, cases of stroke, or reinterventions were recorded in the triple-branched group. Four mortalities, 19 disabling strokes, and 50 reinterventions were recorded in the double-branched group within 30 postoperative days. Target vessel patency was maintained in all patients in the triple-branched group, while vessel patency was maintained in 74.0% of patients in the double-branched group. CONCLUSION: Outcomes associated with the triple-branched group are consistent with those reported in the literature. Our data suggest that EAR with the RELAY™ endograft is associated with favourable clinical outcomes and clinical efficacy. Further comparative research into EAR devices is needed.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Estudos Retrospectivos , Respeito , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Desenho de Prótese
4.
Ann Vasc Surg ; 94: 8-13, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36179943

RESUMO

BACKGROUND: Advances in surgery over the last few decades has led to the development and widespread utilization of thoracic endovascular aortic repair (TEVAR). TEVAR, due to its minimally invasive nature and potential superior outcomes, is now becoming a key focus of interest in treating pathologies of the aortic arch, which has traditionally been treated with open surgical repair. We present our findings of our international multicentre dataset documenting the efficacy of the single-branched RELAY™ endograft in terms of technical success, postoperative outcomes, and reintervention rates. METHODS: Prospective data were collected and retrospectively analyzed with descriptive and distributive analysis between January 2019 and January 2022 from 17 patients treated with RELAY single-branched endoprostheses from centers across Europe. Follow-up data from 30 days and 6 months, 12 months, and 24 months postoperatively was included. Patient follow-up was evaluated in terms of postoperative outcomes, target vessel patency, and reintervention rates. RESULTS: Technical success was achieved in all 17 patients (100%) and there were no postoperative disabling or nondisabling strokes in our single-branched RELAY cohort. The target vessel patency remained 100% during the first 30 days postoperatively; however, by the end of the follow-up period (24 months), target vessel patency was achieved in 93.7% of the patients. There were no reinterventions or deaths during the full study duration using the single-branched RELAY stent-graft. CONCLUSIONS: These results with the single-branched RELAY stent graft demonstrate favorable outcomes in comparison to the literature and demonstrate the feasibility of treatment of aortic pathology with this single-branched graft in the future. Further studies with larger patient cohorts will help us to accumulate evidence for the feasibility of the single-branched RELAY stent graft for aortic arch surgery in the future.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Procedimentos Endovasculares/efeitos adversos , Stents
5.
J Card Surg ; 37(11): 3863-3864, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36069162

RESUMO

BACKGROUND: Frozen elephant trunk has in recent times become a mainstay for total arch replacement in aortovascular surgery and is indicated to treat a spectrum of complex aortic pathologies. However, despite associated excellent postoperative results it is incredibly important to recognize potential adverse complications such as negative aortic remodeling, endoleak, and distal stent-graft induced new entry so that outcomes can be further improved. AIM OF THE STUDY: Below we provide commentary on a recent article in the Journal of Cardiac Surgery discussing the topic. CONCLUSIONS: Despite the fascinating outcomes of this systematic review and meta-analysis the heterogeneity of the literature regarding these adverse outcomes remains an issue which can only be solved with large multicenter trials directly comparing graft types as well as indications for surgery.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Endoleak/etiologia , Humanos , Stents
6.
J Card Surg ; 36(10): 3820-3830, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34310731

RESUMO

BACKGROUND: Type B aortic dissection (TBAD), is defined as a dissection involving the aorta distal to left subclavian artery with the ascending aorta and the aortic arch not affected. TBAD is classified due to the time frame and presence of complications. Complicated TBAD (co-TBAD) patients have a greater mortality rate than uncomplicated TBAD (un-TBAD) and thoracic endovascular aortic repair (TEVAR) is considered the gold-standard intervention for these clinical challenges. METHODS: We undertook a systematic review of the literature regarding TEVAR intervention in co-TBAD and un-TBAD. A comprehensive search was undertaken across four major databases and was evaluated and assessed until June 2020. RESULTS: A total of 16,104 patients were included in the study (7772 patients co-TBAD and 8352 un-TBAD). A significantly higher proportion of comorbidities were seen in co-TBAD patients compared with un-TBAD. Acute dissection was more frequent in the co-TBAD group (73.55% vs. 66.91%), while chronic dissection was more common in un-TBAD patients (33.8% vs. 70.73%). Postprocedure stroke was higher in co-TBAD (5.85% vs. 3.92%; p < .01), while postprocedural renal failure was higher in un-TBAD patients (7.23 vs. 11.38%; p < .01). No difference was observed in in-hospital mortality however the 30 days mortality was higher in the co-TBAD group. One-year survival was higher in the uncomplicated group but this difference was not observed in the 5-year survival. CONCLUSION: In our analysis we can appreciate that despite significantly higher comorbidities in the co-TBAD cohort, there was no difference in in-hospital mortality between the two groups and the 5-year survival did not have any difference.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Card Surg ; 36(5): 1806-1813, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33547714

RESUMO

Non-A non-B aortic dissections are an infrequent occurrence and represent a small proportion of aortic dissections. Treating this life-threatening medical emergency often requires surgeons to undertake some one of the most challenging surgical or endovascular cases in medicine. This literature review aims to define and classify non-A non-B dissections, describe their epidemiology as well as their pathology. This review also aims to discuss the range of surgical techniques employed in their treatment and management and to investigate the patient outcomes associated with each technique.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Stents , Resultado do Tratamento
8.
Eur J Trauma Emerg Surg ; 47(3): 757-762, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32715331

RESUMO

BACKGROUND: Artificial intelligence (AI) is a field involving computational simulation of human intelligence processes; these applications of deep learning could have implications in the specialty of emergency surgery (ES). ES is a rapidly advancing area, and this review will outline the most recent advances. METHODS: A literature search encompassing the uses of AI in surgery was conducted across large databases (Pubmed, OVID, SCOPUS). Two doctors (LR, CH) both collated relevant papers and appraised them. Papers included were published within the last 5 years, and a "snowball effect" used to collate further relevant literature. RESULTS: AI has been shown to provide value in predicting surgical outcomes and giving personalised patient risks based on inputted data. Further to this, image recognition technology within AI has showed success in fracture identification and breast cancer diagnosis. Regarding theatre presence, supervised robots have carried out suturing and anastomosis of bowel in controlled environments to a high standard. CONCLUSION: AI has potential for integration across surgical services, from diagnosis to treatment, and aiding the surgeon in key decision-making for risks per patient. Fully automated surgery may be the future, but at present, AI needs human supervision.


Assuntos
Inteligência Artificial , Automação , Procedimentos Cirúrgicos Operatórios , Previsões , Humanos , Cirurgiões
9.
Int J Angiol ; 28(4): 215-225, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31787819

RESUMO

Large-vessel vasculitis encompasses the spectrum of vasculitides, which pathologically cause chronic granulomatous inflammatory changes, primarily in the aorta and its major branches. These patients are at risk of developing life-threatening aortic lesions that, without recognition and prompt treatment, can cause detrimental effects. Many provocative issues surrounding large-vessel vasculitis and its surgical treatment still remain, spanning from recognition to management. In this review, we discuss the main large-vessel vasculitides, Takayasu's arteritis and giant cell arteritis. We include the key points and current controversies surrounding diagnostic imaging, timing of interventions, and patient outcomes.

10.
J Card Surg ; 34(12): 1577-1590, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31600005

RESUMO

Aortic valve stenosis (AS) is the most common valvular pathology and has traditionally been managed using surgical aortic valve replacement (SAVR). A large proportion of affected patient demographics, however, are unfit to undergo major surgery given underlying comorbidities. Since its introduction in 2002, transcatheter aortic valve implantation (TAVI) has gained popularity and transformed the care available to different-risk group patients with severe symptomatic AS. Specific qualifying criteria and refinement of TAVI techniques are fundamental in determining successful outcomes for intervention. Given the successful applicability in high-risk patients, TAVI has been further developed and trialed in intermediate and low-risk patients. Within intermediate-risk patient groups, TAVI was shown to be noninferior to SAVR evaluating 30-d mortality and secondary endpoints such as the risk of bleeding, development of acute kidney injury, and length of admission. The feasibility of expanding TAVI procedures into low-risk patients is still a controversial topic in the literature. A number of trials have recently been published which demonstrate TAVI as noninferior and even superior over SAVR for primary study endpoints.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Humanos , Seleção de Pacientes
11.
Braz J Cardiovasc Surg ; 34(4): 464-471, 2019 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-31454201

RESUMO

OBJECTIVE: Cerebrospinal fluid (CSF) drainage is a technique that has significantly reduced the incidence of spinal cord ischaemia (SCI). We present results of a systematic review to assess the literature on this topic in relation to thoracoabdominal aortic aneurysm repair (TAAR). METHODS: Major medical databases were searched to identify papers related to CSF biomarkers measured during TAAAR. RESULTS: Fifteen papers reported measurements of CSF biomarkers with 265 patients in total. CSF biomarkers measured included S-100ß, neuron-specific endolase (NSE), lactate, glial fibrillary acidic protein A (GFPa), Tau, heat shock protein 70 and 27 (HSP70, HSP27), and proinflammatory cytokines. Lactate and S-100ß were reported the most, but did not correlate with SCI, which was also the case with NSE and TAU. GFPa showed significant CSF level rises, both intra and postoperative in patients who suffered SCI and warrants further investigation, similar results were seen with HSP70, HSP27 and IL-8. CONCLUSIONS: Although there is significant interest in this topic, there still remains a significant lack of high-quality studies investigating CSF biomarkers during TAAR to detect SCI. A large and multicentre study is required to identify the significant role of each biomarker.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Biomarcadores/líquido cefalorraquidiano , Técnicas Eletroquímicas/métodos , Fosfopiruvato Hidratase/sangue , Isquemia do Cordão Espinal/líquido cefalorraquidiano , Biomarcadores/sangue , Drenagem , Humanos , Ácido Láctico/sangue , Ácido Láctico/líquido cefalorraquidiano , Proteínas S100/sangue , Proteínas S100/líquido cefalorraquidiano , Isquemia do Cordão Espinal/sangue
12.
Rev. bras. cir. cardiovasc ; 34(4): 464-471, July-Aug. 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1020500

RESUMO

Abstract Objective: Cerebrospinal fluid (CSF) drainage is a technique that has significantly reduced the incidence of spinal cord ischaemia (SCI). We present results of a systematic review to assess the literature on this topic in relation to thoracoabdominal aortic aneurysm repair (TAAR). Methods: Major medical databases were searched to identify papers related to CSF biomarkers measured during TAAAR. Results: Fifteen papers reported measurements of CSF biomarkers with 265 patients in total. CSF biomarkers measured included S-100ß, neuron-specific endolase (NSE), lactate, glial fibrillary acidic protein A (GFPa), Tau, heat shock protein 70 and 27 (HSP70, HSP27), and proinflammatory cytokines. Lactate and S-100ß were reported the most, but did not correlate with SCI, which was also the case with NSE and TAU. GFPa showed significant CSF level rises, both intra and postoperative in patients who suffered SCI and warrants further investigation, similar results were seen with HSP70, HSP27 and IL-8. Conclusions: Although there is significant interest in this topic, there still remains a significant lack of high-quality studies investigating CSF biomarkers during TAAR to detect SCI. A large and multicentre study is required to identify the significant role of each biomarker.


Assuntos
Humanos , Fosfopiruvato Hidratase/sangue , Biomarcadores/líquido cefalorraquidiano , Aneurisma da Aorta Torácica/cirurgia , Isquemia do Cordão Espinal/líquido cefalorraquidiano , Técnicas Eletroquímicas/métodos , Biomarcadores/sangue , Proteínas S100/líquido cefalorraquidiano , Proteínas S100/sangue , Drenagem , Ácido Láctico/líquido cefalorraquidiano , Ácido Láctico/sangue , Isquemia do Cordão Espinal/sangue
13.
Semin Thorac Cardiovasc Surg ; 31(4): 664-667, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31283988

RESUMO

There is a lack of evidence on multiple levels for appropriate recognition, management, and outcome results in Type A aortic dissection management in the United Kingdom. A huge amount of retrospective data exists in the literature which provides nonmeaningful prospect to a service that meets the current era. Electronic searches were performed on PubMed and Cochrane databases with no limits placed on dates. Search terms were charted to MeSH terms and combined using Boolean operations, and also used as key words. Papers were selected on the basis of title and abstract. The reference lists of selected papers were reviewed to identify any relevant papers that might be suitable for inclusion in the study. Papers were selected based on providing primary end points of death, rupture, or dissection and/or information regarding aortic aneurysm growth. Papers were not excluded based on patient population age. We demonstrated the lack of evidence for quality outcomes in type A aortic dissection in the United Kingdom. This highlighted the unwarranted variation seen in this entity and the caveats needed to improve structuring of type A aortic dissection from early identification in emergency departments to arrival at destination site for optimum intervention. Emergency services should be restructured to meet the immediate affirmation of diagnosis with gold standard imaging modality available. Management of this dire disease should be instituted at local hospitals prior to transportation and results should be audited regularly to improve quality outcomes. Attempts should be made to create local area networks to improve the efficiencies and outcomes of the service and transfer to centers with concentration of expertise. Recognition of regional networks by the UK Government Care Quality Commission should in part based on cumulative evidence sought after from virtual multidisciplinary teams. Unwarranted variation is an avenue that requires to be addressed to rise with service provision that meets our patients aspiration and be of current evidence in the 21st era.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Serviços Centralizados no Hospital/organização & administração , Prestação Integrada de Cuidados de Saúde/organização & administração , Medicina Estatal/organização & administração , Procedimentos Cirúrgicos Vasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Humanos , Melhoria de Qualidade/organização & administração , Indicadores de Qualidade em Assistência à Saúde/organização & administração , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Reino Unido/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
14.
J Card Surg ; 34(6): 482-494, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31012137

RESUMO

Bicuspid aortic valves (BAVs) are the most common congenital cardiac condition and are characterized by a structural abnormality whereby the aortic valve is composed of two leaflets instead of being trileaflet. It is linked to an increased risk for a variety of complications of the aorta, many with an immunological pathogenesis. The aim of this study is to review and analyze the literature regarding immunological processes involving BAVs, associated common pathologies, and their incidence in the population. This study will also examine current trends in surgical and therapeutic approaches to treatment and discuss the future direction of BAV treatment.


Assuntos
Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/imunologia , Doenças do Sistema Imunitário/etiologia , Doenças do Sistema Imunitário/imunologia , Valva Aórtica/imunologia , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/terapia , Humanos , Doenças do Sistema Imunitário/epidemiologia , Incidência , Risco , Substituição da Valva Aórtica Transcateter
15.
Innovations (Phila) ; 13(6): 404-416, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30543577

RESUMO

OBJECTIVE: The aim of the study was to compare hemodynamic and perioperative outcomes of stented against stentless aortic valve replacement in patients with small aortic root (21 mm or less). METHODS: A comprehensive search was undertaken among the four major databases (PubMed, Embase, Scopus, and Ovid) to identify all randomized and nonrandomized controlled trials comparing stentless to stented bioprosthetic valves in small aortic root patients. Odds ratios, weighted mean differences, or standardized mean differences and their 95% confidence intervals were analyzed. RESULTS: A total of seven studies with a total of 965 patients fulfilled the inclusion criteria. There was no significant difference in preoperative baselines including mean age between both groups (P = 0.08), peak aortic valve gradient (P = 0.06), and effective orifice area (P = 0.28), whereas higher mean aortic valve gradient in the stented group (P = 0.007). No difference in cardiopulmonary bypass time (P = 0.74), aortic cross-clamp times (P = 0.88), intensive care unit stay (P = 0.13), and stroke rate (P = 0.56) were noted. However, stented group of patients showed higher rate of patient prosthesis mismatch (P = 0.0001) and longer total hospital stay (P = 0.002). Postoperatively, stentless group showed lower peak and mean aortic valve gradient (P = 0.003 and P = 0.008, respectively) with a better effective orifice area (P < 0.00001) at 6 months of follow-up. Mortality rates while in-hospital and at 1 year were similar in both groups (P = 0.94 and P = 0.86, respectively). CONCLUSIONS: Stentless aortic valves offer superior short-term hemodynamic outcomes in patients with small aortic root when compared with stented aortic valves. Although both groups have similar perioperative complications rates, stentless valves bring about a shorter hospital stay. A further large multicenter randomized controlled trial should address the longer-term benefit of stentless aortic valve over stented valve.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Stents , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Bioprótese/estatística & dados numéricos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Stents/efeitos adversos , Stents/estatística & dados numéricos
16.
Innovations (Phila) ; 12(4): 259-264, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28759542

RESUMO

OBJECTIVE: Minimally invasive thoracic surgical procedures, performed with or without the assistance of a robot, have gained popularity over the last decade. They have increasingly become the choice of intervention for a number of thoracic surgical operations. Minimally invasive surgery decreases postoperative pain, hospital stay and leads to a faster recovery in comparison with conventional open methods. Minimally invasive techniques to perform a thymectomy include video-assisted thoracoscopic surgery (VATS) or robotic-assisted thoracoscopic surgery (RATS). In this study, we aim to systematically review and interrogate the literature on minimally invasive thymectomy and draw a meta-analysis on the outcomes between the two approaches. METHODS: An extensive electronic health database search was performed on all articles published from inception to May 2015 for studies describing outcomes in VATS and RATS thymectomy. RESULTS: A total of 350 patients were included in this study, for which 182 and 168 patients underwent RATS and VATS thymectomy, respectively. There were no recorded in-hospital deaths for either procedure. There was no statistical difference in conversion to open, length of hospital stay, or postoperative pneumonia. Operational times for RATS thymectomy were longer. CONCLUSIONS: The VATS and RATS thymectomy offer good and safe operative and perioperative outcomes. There is little difference between the two groups. However, there is poor evidence basis for the long-term outcomes in minimally invasive procedures for thymectomy. It is imperative that future studies evaluate oncological outcomes both short and long term as well as those related to safety.


Assuntos
Procedimentos Cirúrgicos Robóticos , Cirurgia Torácica Vídeoassistida , Timectomia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miastenia Gravis/cirurgia , Duração da Cirurgia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/mortalidade , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Cirurgia Torácica Vídeoassistida/mortalidade , Cirurgia Torácica Vídeoassistida/estatística & dados numéricos , Timectomia/efeitos adversos , Timectomia/métodos , Timectomia/mortalidade , Timectomia/estatística & dados numéricos , Timo/cirurgia , Neoplasias do Timo/cirurgia , Resultado do Tratamento
17.
Innovations (Phila) ; 10(5): 342-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26536078

RESUMO

OBJECTIVE: Paraplegia remains the most feared and a devastating complication after descending and thoracoabdominal aneurysm operative repair (DTA and TAAAR). Neuromonitoring, particularly use of motor-evoked potentials (MEPs), for this surgery has gained popularity. However, ambiguity remains regarding its use and benefit. We systematically reviewed the literature to assess the benefit and applicability of neuromonitoring in DTA and TAAAR. METHODS: Electronic searches were performed on 4 major databases from inception until February 2014 to identify relevant studies. Eligibility decisions, method quality, data extraction, and analysis were performed according to predefined clinical criteria and end points. RESULTS: Among the studies matching our inclusion criteria, 1297 patients had MEP monitoring during DTA and TAAAR. In-hospital mortality was low (6.9% ± 3.6). Immediate neurological deficit was low (3.5% ± 2.6). In one third of patients (30.4% ± 14.2), the MEPs dropped below threshold, which were 30.4% and 29.4% with threshold levels of 75% and 50%, respectively. A range of surgical techniques were applied after reduction in MEPs. Most patients whose MEPs dropped and remained below threshold had immediate permanent neurological deficit (92.0% ± 23.6). Somatosensory-evoked potentials were reported in one third of papers with little association between loss of somatosensory-evoked potentials and permanent neurological deficit (16.7% ± 28.9%). CONCLUSIONS: We demonstrate that MEPs are useful at predicting paraplegia in patients who lose their MEPs and do not regain them intraoperatively. To date, there is no consensus regarding the applicability and use of MEPs. Current evidence does not mandate or support MEP use.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Monitorização Neurofisiológica Intraoperatória , Aneurisma da Aorta Torácica/fisiopatologia , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Paraplegia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...